Embers Bristol
Tel: 0117 925 1115

Latest Case Studies

Inset stove installation

10-September-2016
10-September-2016 13:20
in General
by Admin


ENQUIRY

The customer wanted to remove the wooden surround and replace the existing fire with an inset wood burning stove.

SURVEY
We popped over to take a look at the room, chimney aperture and access to the stack. We suggested - a 5kW stove would suit the room size, a chimney sweep would be needed and the access was fine. We issued a estimate detailing the variables that may incur once the existing fireplace had been removed.

Embers Bristol Stove Installation
Survey photo

After the estimate was accepted we booked the prep work and installation. The duration was two days with the preparation work on the first and install on the second.

PREP WORK

We removed the existing fireplace and created a smaller opening to accomodate the stove.
We retained the existing front hearth as it complied with building regs.

INSTALLATION
The stove chosen was the STOVAX Riva 40
We installed a 10 meter 316 grade flxible liner.

Embers Bristol Stove Install
Completed installation photo

Contact Us

0117 925 1115

Visit our showroom:
Ember Bristol,
117-119 St Georges Road,
College Green,
Bristol,
BS1 5UW

Opening Hours

Tues - Fri - 10.30 - 17.30
[Closed between 12.30 - 13.30]
Sat - 10.30 - 15.00
[Closed between 12.30 - 13.00]
Sun - Mon - Closed

Please note we will be closed on the 2nd, 9th & 25th of April

686626